INSPECTOR III       

Home.gif (1443 bytes)

Products.gif (1669 bytes)

Contact Us.gif (1706 bytes)

FAQs.gif (1460 bytes)

Specifications.gif (1728 bytes)

 

Made in U.S.A.
Unconditionally
Guaranteed


Download Manual


TEST


• Wiring ability to handle 0, 10, 15 or 20 AMP loads
to code recommendations
• All Splices and Connections
• Line voltage under load
• Wiring Configuration
• Ground Line Impedance
• GFCI For proper operation
• AFCI for proper connection and Operation
• Available Fault Current



Inspector III  $319.00

 

 





THE INSPECTOR III
 
• Show customers faulty wiring without removing outlets or cover plates.
• Verify that wiring meets electical code recommendations for voltage drop.
• Avoid embarrassing and expensive call backs.
• Save time and money by eliminating guess work.
 
WHY YOU NEED THE INSPECTOR III
 

You need it because your customers are the #1 priority. With the Inspector™ III you can show them faulty wiring without removing outlets, cover plates or panel covers. Testing branch circuits for load carrying ability will give your customers assurance and comfort (not to mention a second opinion)! Last, but not least, you can protect your customers from personal injury or damage caused by faulty GFCIs, bad grounds, or mis-wired AFCIs.

 
WHAT THE INSPECTOR III WILL DO FOR YOU
The Inspector™ III will verify that wiring meets electrical code recommendations for voltage drop under load. It will also show how much specific drop is on the hot and the neutral conductor. This is an outstanding way to check splices, connections and conductor quality which is crucial to computers and sensitive electronic equipment. Since the Inspector™ III checks all aspects of wiring quality, you will avoid embarrassing and costly call backs for years to come! Many electricians have told us this product helps them avoid accidents that can lead to possible lawsuits. The bottom line is you’re going to save time and money by eliminating the guess work associated with remodeling, new construction and maintaining wiring systems!
 

HOW IT WORKS

 

The Inspector™ III draws a small load on the line for a short period of time. Next, it uses internal logic to calculate the percentage of voltage drop. You never actually put the full load on the line. This product will not trip breakers or put unnecessary stress on electrical lines. The load measurement is taken independent of voltage. This assures the indicated percentage of voltage drop will be correct and not read high or low due to varying line voltage.

INSPECTOR III   SPECIFICATIONS

   
Load: Constant
0, 10, 15 or 20 AMP simulation regardless of line voltage
Operating Voltage:
95-140 VAC
   
Battery:
9V Alkaline
   
Fuse:
1/2 Amp, 125 Volt
   
GFI Trip:
6.0 mA nominal to trip GFI, 30 mA to trip RCD
   
AFCI Trip:
Up to 8, 120 AMP pulses within 1/2 second period
   
Operating Temperature:
32ºF to 120ºF (0º - 50ºC)
   
Accuracy:
+/-2%, +/- 2 digits

 